中文
Your Position
 PRODCUCT CENTER
A series single stage low speed centrifugal blower
    Publish time 2017-07-30 11:32    
A series single stage low speed centrifugal blower

Product details

Derived Models

The following models are derived from the above three models:

●Sewage treatment blower capacity: 50~600m3/min pressure rise:49.0~98kPa

●Desulfurization&oxidation blower capacity: 60~800m3/minpressure rise: 49.0~150kPa

●Sulfur dioxide blower capacity:200~2000m3/minpressure rise: 26.4~53.9kPa

●Gas-making furnace blower capacity: 300~1500m3/minpressure rise: 23.5~34.3kPa

●Cupola blower capacity:50~350m3/minpressure rise: 9.8~29.4kPa

●Smelting furnace blower capacity:100~1000m3/minpressure rise: 49.0~150kPa

●Coal gas blowercapacity:100~1250m3/minpressure rise: 19.6~53.9kPa

●Coal flotation&washing blowercapacity:50~500m3/minpressure rise:19.6~68.6kPa

Model Selection

Model Introduction


 
 
 

For example:

C300–1.7/1.0

It means a multistage centrifugal blower, when temperature is 20℃, intake pressure is 1.0kgf/cm2(98kPa), relative humidity is 50%, the capacity is 300 m3/min, and discharge pressure is 1.7kgf/cm2(pressure rise 68.6kPa).

Model Selection Drawing


 
 
 

● Features:

◎ Due to the advanced design of aerodynamic, the impeller is of high efficiency..

◎ The casing is of horizontal division welding structure, simple and light in weight.

◎ The advanced wearing-resistant and anti-adhesion technology is applied to deal with the medium with many dust, so the service life of blower is long.

◎ Flat performance curve means the stable working range is wide.

◎ AI single-stage and cantilever construction is applied to the blower with small and medium capacity.

◎ AII single-stage and double supporting construction is applied to the blower with large capacity.

● Typical Performance Data of Single-stage Centrifugal Blower

Type

Intake condition

pressure rise (kpa)

La(kW)

Po(kW)

deliver medium

capacity (m3/min)

pressure (kgf/cm2)

temperature (℃)

AI200-1.20/1.0

air

200

1.0

20

19.6

95.0

125

AI250-1.30/1.0

air

250

1.0

20

29.4

168

220

AI250-1.35/1.0

air

250

1.0

20

34.3

196

250

AI250-1.27/1.0

coal gas

250

1.0

30

26.5

185

220

AI250-1.26/0.95

Include SO2

250

0.95

40

30

173

220

AI300-1.25/1.0

air

300

1.0

20

24.5

160

185

AI300-1.35/1.0

air

300

1.0

20

34.3

230

280

AI300-1.13/1.05

Coke Oven Gas

300

1.05

35

7.84

65.0

90

AI300-1.24/0.95

Include SO2

300

0.95

40

28.4

195

250

AI350-1.12/0.95

coal gas

350

0.95

40

16.7

92

110

AI350-1.24/0.95

Include SO2

350

0.95

40

28.4

195

250

AI400-1.35/1.0

air

400

1.0

20

34.3

315

355

AI400-1.24/0.95

Include SO2

400

0.95

40

28.4

261

315

AI500-1.30/1.0

air

500

1.0

20

29.4

336

400

AI500-1.24/1.0

coal gas

500

1.0

30

23.5

241

280

AI500-1.22/0.95

Include SO2

500

0.95

40

26.5

296

355

AI600-1.2/1.0

air

600

1.0

20

19.6

265

315

AI750-1.24/1.0

air

750

1.0

20

23.5

340

400

AI800-1.3/1.0

air

800

1.0

20

29.4

515

630

AI800-1.19/1.03

coal gas

800

1.03

35

15.7

305

355

AI900-1.04/0.842

coal gas

900

0.842

65

19.6

410

450

AII1000-1.17/1.05

coal gas

1000

1.03

35

12

265

315

AII1200-1.28/1.0

air

1200

1.0

20

27.4

690

800

AII1400-1.2/1.0

air

1400

1.0

20

19.6

579

710

AII1500-1.0/0.73

coal gas

1500

0.73

50

26.5

805

900

AII1600-1.0/0.73

coal gas

1600

0.73

50

26.5

860

1000

AII1800-1.0/0.73

coal gas

1800

0.73

50

26.5

960

1120

AII2000-1.0/0.73

coal gas

2000

0.73

50

26.5

1070

1250

AII2000-1.35/1.0

air

2000

1.0

20

34.3

1370

1600

● Dimensions of Single-stage Low Speed Centrifugal Blower

Installation Drawing of AI600-800 Single-stage Low Speed Centrifugal Blower

(This is only for reference, the foundation should be built on the basis of contract drawing.)


 
 
 

Installation Drawing of AII1500-2000 Single-stage Low Speed Centrifugal Blower

(This is only for reference, the foundation should be built on the basis of contract drawing.)


 
 

● Supply Scope of Single-stage Low Speed Centrifugal Blower

No.

Standard

Optional

Name

Qty

Name

Qty

1

Blower

1

Inlet control valve

1

2

Lubricating device

1

Outlet valve

1

3

Motor

1

Inlet flexible joint

1

4

Coupling

1

Outlet flexible joint

1

5

Coupling protector

1

Primary instrument

1

6

Anchor bolt, nut, washer

1

Spot control cabinet

1

* For the blower with rolling bearing, the lubricating device is included in the blower, for the blower with sliding bearing, the thin oil station is equipped.