Derived Models
The following models are derived from the above three models:
●Sewage treatment blower capacity: 50~600m3/min pressure rise:49.0~98kPa
●Desulfurization&oxidation blower capacity: 60~800m3/minpressure rise: 49.0~150kPa
●Sulfur dioxide blower capacity:200~2000m3/minpressure rise: 26.4~53.9kPa
●Gas-making furnace blower capacity: 300~1500m3/minpressure rise: 23.5~34.3kPa
●Cupola blower capacity:50~350m3/minpressure rise: 9.8~29.4kPa
●Smelting furnace blower capacity:100~1000m3/minpressure rise: 49.0~150kPa
●Coal gas blowercapacity:100~1250m3/minpressure rise: 19.6~53.9kPa
●Coal flotation&washing blowercapacity:50~500m3/minpressure rise:19.6~68.6kPa
Model Selection
Model Introduction
For example:
C300–1.7/1.0
It means a multistage centrifugal blower, when temperature is 20℃, intake pressure is 1.0kgf/cm2(98kPa), relative humidity is 50%, the capacity is 300 m3/min, and discharge pressure is 1.7kgf/cm2(pressure rise 68.6kPa).
Model Selection Drawing
● Features:
◎ Due to the advanced design of aerodynamic, the impeller is of high efficiency..
◎ The casing is of horizontal division welding structure, simple and light in weight.
◎ The advanced wearing-resistant and anti-adhesion technology is applied to deal with the medium with many dust, so the service life of blower is long.
◎ Flat performance curve means the stable working range is wide.
◎ AI single-stage and cantilever construction is applied to the blower with small and medium capacity.
◎ AII single-stage and double supporting construction is applied to the blower with large capacity.
● Typical Performance Data of Single-stage Centrifugal Blower
Type |
Intake condition |
pressure rise (kpa) |
La(kW) |
Po(kW) |
|||
deliver medium |
capacity (m3/min) |
pressure (kgf/cm2) |
temperature (℃) |
||||
AI200-1.20/1.0 |
air |
200 |
1.0 |
20 |
19.6 |
95.0 |
125 |
AI250-1.30/1.0 |
air |
250 |
1.0 |
20 |
29.4 |
168 |
220 |
AI250-1.35/1.0 |
air |
250 |
1.0 |
20 |
34.3 |
196 |
250 |
AI250-1.27/1.0 |
coal gas |
250 |
1.0 |
30 |
26.5 |
185 |
220 |
AI250-1.26/0.95 |
Include SO2 |
250 |
0.95 |
40 |
30 |
173 |
220 |
AI300-1.25/1.0 |
air |
300 |
1.0 |
20 |
24.5 |
160 |
185 |
AI300-1.35/1.0 |
air |
300 |
1.0 |
20 |
34.3 |
230 |
280 |
AI300-1.13/1.05 |
Coke Oven Gas |
300 |
1.05 |
35 |
7.84 |
65.0 |
90 |
AI300-1.24/0.95 |
Include SO2 |
300 |
0.95 |
40 |
28.4 |
195 |
250 |
AI350-1.12/0.95 |
coal gas |
350 |
0.95 |
40 |
16.7 |
92 |
110 |
AI350-1.24/0.95 |
Include SO2 |
350 |
0.95 |
40 |
28.4 |
195 |
250 |
AI400-1.35/1.0 |
air |
400 |
1.0 |
20 |
34.3 |
315 |
355 |
AI400-1.24/0.95 |
Include SO2 |
400 |
0.95 |
40 |
28.4 |
261 |
315 |
AI500-1.30/1.0 |
air |
500 |
1.0 |
20 |
29.4 |
336 |
400 |
AI500-1.24/1.0 |
coal gas |
500 |
1.0 |
30 |
23.5 |
241 |
280 |
AI500-1.22/0.95 |
Include SO2 |
500 |
0.95 |
40 |
26.5 |
296 |
355 |
AI600-1.2/1.0 |
air |
600 |
1.0 |
20 |
19.6 |
265 |
315 |
AI750-1.24/1.0 |
air |
750 |
1.0 |
20 |
23.5 |
340 |
400 |
AI800-1.3/1.0 |
air |
800 |
1.0 |
20 |
29.4 |
515 |
630 |
AI800-1.19/1.03 |
coal gas |
800 |
1.03 |
35 |
15.7 |
305 |
355 |
AI900-1.04/0.842 |
coal gas |
900 |
0.842 |
65 |
19.6 |
410 |
450 |
AII1000-1.17/1.05 |
coal gas |
1000 |
1.03 |
35 |
12 |
265 |
315 |
AII1200-1.28/1.0 |
air |
1200 |
1.0 |
20 |
27.4 |
690 |
800 |
AII1400-1.2/1.0 |
air |
1400 |
1.0 |
20 |
19.6 |
579 |
710 |
AII1500-1.0/0.73 |
coal gas |
1500 |
0.73 |
50 |
26.5 |
805 |
900 |
AII1600-1.0/0.73 |
coal gas |
1600 |
0.73 |
50 |
26.5 |
860 |
1000 |
AII1800-1.0/0.73 |
coal gas |
1800 |
0.73 |
50 |
26.5 |
960 |
1120 |
AII2000-1.0/0.73 |
coal gas |
2000 |
0.73 |
50 |
26.5 |
1070 |
1250 |
AII2000-1.35/1.0 |
air |
2000 |
1.0 |
20 |
34.3 |
1370 |
1600 |
● Dimensions of Single-stage Low Speed Centrifugal Blower
Installation Drawing of AI600-800 Single-stage Low Speed Centrifugal Blower
(This is only for reference, the foundation should be built on the basis of contract drawing.)
Installation Drawing of AII1500-2000 Single-stage Low Speed Centrifugal Blower
(This is only for reference, the foundation should be built on the basis of contract drawing.)
● Supply Scope of Single-stage Low Speed Centrifugal Blower
No. |
Standard |
Optional |
||
Name |
Qty |
Name |
Qty |
|
1 |
Blower |
1 |
Inlet control valve |
1 |
2 |
Lubricating device |
1 |
Outlet valve |
1 |
3 |
Motor |
1 |
Inlet flexible joint |
1 |
4 |
Coupling |
1 |
Outlet flexible joint |
1 |
5 |
Coupling protector |
1 |
Primary instrument |
1 |
6 |
Anchor bolt, nut, washer |
1 |
Spot control cabinet |
1 |
* For the blower with rolling bearing, the lubricating device is included in the blower, for the blower with sliding bearing, the thin oil station is equipped.